Set the CURRENT LIMIT ADJ potentiometer to the desired
maximum output current, or set it fully clockwise.
4-3.
TROUBLE SYMPTOMS AND SUGGESTED REMEDIES
a. Circuit faults can be isolated most rapidly by measuring
the voltage and resistance. Use the data given on the schematic
diagram in the Appendix as a first stop in servicing the supply.

CAUTION

WHEN UNSOLDERING SEMICONDUCTORS FOR TEST, USE A
HEAT SINK TO PREVENT THERMAL DAMAGE. A LONG NOSE
PLIERS BETWEEN THE SEMICONDUCTOR AND THE SOLDER
JUNCTION IS ADEQUATE. NEVER OPERATE THE POWER
SUPPLY WITH ANY LEADS DISCONNECTED OR SEMICONDUCTORS
REMOVED. OPERATING POTENTIALS IN THE DC AMPLIFIER
MAY CHANGE RADICALLY WHEN A COMPONENT IS REMOVED OR
DISCONNECTED.

b. Power Supply Does Not Go On : If the OVEN and AC lamps
do not light, check the AC fuse. If the fuse blows repeatedly,
check the oven circuit and diodes CR1, CR2 and CR4 through CR7.
Use an ohmmeter to take a resistance reading across each diode.
Then, reverse the meter leads and take another reading. If one
reading is not at least five times greater than the other, the
diode is defective. If one diode in any pair is defective, replace
both. A short circuit in one will produce high surge currents in
the other, which can result in junction damage.

c. No DC Output Voltage: If both the AC and OVEN lamps light,
but no output voltage is available, insure that the CURRENT LIMIT ADJ
control is not turned fully counterclockwise. Set the meter switch
to MA and increase the output voltage. If no current is indicated,
check the DC fuse and input capacitor C1. If current is present
when the output—voltage controls are adjusted, check safety diode
CR12 and for incorrect programming or sensing connections. Diode
CR12 is connected in the opposite polarity to the DC output voltage.
If the reverse current flow is greater than 1 ampere, this diode
may weld, placing a permanent short circuit across the supply out-
put. Normal operation can be restored by replacing the diode
(located on the amplifier board).

d. Regulator Failure : Check for correct potentials on ampli-
fier transistors, voltage reference, etc. If any voltage appears
incorrect, disconnect AC power and make a rapid check for defective
transistors. This can be done without removing the transistors from
the circuit. Use an ohmmeter sot to its low resistance scale (R x1)
and measure the forward and reverse resistances at the collector-base
and base—emitter junctions. A resistance ratio of less than 5 to 1
indicates that the transistor is defective. Carefully remove it and
check it on a transistor checker.