5

2005

Parameter
Specifications
Remote Programming Rear panel barrier block terminals are provided for remote programming of the output voltage. The ratio of the programming resistance to the output voltage is 1000 ohms per volt. The programming accuracy is better than 0.01% of the resistance value, including the resistance of the programming leads.

Metering
Front panel volt—ammeter permits monitoring
output voltage or current with an accuracy
of ±2% of full scale.

NOTE:
This accuracy is considerably less
than that of the power source.

Circuit Protection
The AC line and DC load circuits are
separately fused. The fuses are accessible
at the rear of the unit.

Indicator Lamps

AC Lamp
Lights when AC toggle switch is set to ON
and power is applied to the unit.
OVEN Lamp
Lights when AC input is applied and oven
heater is energized (operates even when AC toggle switch is turned off). Lamp cycles on and off as oven maintains constant temperature environment for critical components.

+10 V Lamp
Lights when RANGE switch is set to 1O—20V
position to indicate that output is 10
volts plus the dial readout.


645
1—3

5