5

2005

Parameter
Specifications
Remote Programming Rear panel barrier block terminals are
provided for remote programming of the
output voltage. The ratio of the program-
ming resistance to the output voltage is
1000 ohms per volt. The programming
accuracy is better than 0.01% of the
resistance value, including the resistance
of the programming leads.

Metering
Front panel volt—ammeter permits monitoring
output voltage or current with an accuracy
of ±2% of full scale.

NOTE:
This accuracy is considerably less
than that of the power source.

Circuit Protection
The AC line and DC load circuits are
separately fused. The fuses are accessible
at the rear of the unit.

Indicator Lamps

AC Lamp
Lights when AC toggle switch is set to ON
and power is applied to the unit.
OVEN Lamp
Lights when AC input is applied and oven
heater is energized (operates even when
AC toggle switch is turned off). Lamp
cycles on and off as oven maintains
constant temperature environment for
critical components.

+10 V Lamp
Lights when RANGE switch is set to 1O—20V
position to indicate that output is 10
volts plus the dial readout.


645
1—3

5